{"product_id":"aithre-turbo-oxygen-maker-digital-installed","title":"Aithre Turbo Oxygen Maker Digital - Installed","description":"\u003ch1\u003eOverview \u003c\/h1\u003e\n\u003cp\u003eThe Aithre Turbo Oxygen Maker with digital flow control is the World's first oxygen generator optimized specifically for light aircraft and general aviation.  With enough oxygen supply to circumnavigate the World many times, the Aithre Turbo Oxygen Maker will unlock your aircraft potential and support your mission, no matter where it takes you.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHOW IT WORKS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Turbo concentrates oxygen real-time while you fly, anytime, anywhere, using a fraction of the capacity of most general aviation electrical alternators. Based on proven pressure swing adsorption technology (PSA), and optimized for general aviation application, the Aithre Turbo packs a punch with continuous \u0026gt;93% pure oxygen at 1.1 - 1.4 LPM using just 6 amps or 80 watts.  \u003c\/p\u003e\n\u003cp\u003eA high-performance compressor pump is used to pressurize intake air and feed it through zeolite sieve beds.  The sieve beds retain the nitrogen in the air and pass oxygen through the adsorption technique (PSA).  PSA is a proven method of oxygen generation in the medical field, but the Turbo is different in that it operates above 10k MSL where the air is thinner.  \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNO BATTERY TO CHARGE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnlike medical portable oxygen concentrators, the Turbo does not use a Lithium battery.  Instead, the Turbo relies exclusively on ship power 12-14V or 24-28V, using the aircraft battery or engine-driven electrical alternator.  At just 80W or approximately 6 amps at 14V supply, the Turbo will fit within virtually any alternator capacity and this results in reduced maintenance, a longer service life, and increased flight safety.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSMALL FOOTPRINT AND WEIGHT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith a small footprint of\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e22.5 cm x 14.5 cm x 15 cm and a weight of just 6.8 lbs.\u003c\/span\u003e\u003cspan\u003e, the Aithre Turbo will free up space and expand useful load as compared to traditional legacy bottle systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eINSTALLED FOR EXPERIMENTAL AIRCRAFT\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Aithre Turbo installed digital system features panel-mounted cannula plugs, remote push-button activation, and hidden built-in plumbing.  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA unique hook mount system is provided for removably securing the Turbo to a wall, floor, or supporting member. While the Turbo requires intake access to fresh air through its side ports, with center of gravity impact minimized, there are many options for mounting: tail-cone, nose-cone (for pusher or twin-engine aircraft), or the baggage compartment.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA complete plumbing kit is provided \u003c\/span\u003ewith tubing, elbows, branches, panel cannula plugs, and placards.  Installation is straightforward: the provided plumbing is routed and secured from the Turbo to each of the stations and the backlit O2 button is electrically routed to the panel.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUTOMATIC DIGITAL FLOW CONTROL OF CONCENTRATED OXYGEN\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Turbo installed digital system features automatic digital flow control of concentrated oxygen.  Medical concentrators often require user control of an analog flow meter to adjust and set the flow rate and the oxygen concentration.  With the Turbo, the flow is set and managed automatically to help support flight safety with predictable and optimized oxygen generation.  Simply push the oxygen button and the oxygen is provided to 1.1 - 1.4 LPM at altitudes up to 18k MSL and \u0026gt;93% concentration. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHEALTHVIEW, AITHRE CONNECT iOS, AND AVIONICS SUPPORT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAithre has pioneered the integration of health biometrics into the avionics of the aircraft, and the Turbo is no exception: the Turbo constantly monitors total flow, onboard temperature, pressure altitude, and faults.  Data is output via BLE to the Aithre Connect iOS app, and optionally to the HealthView.  For supporting avionics, a discrete fault output 0-12V may be connected to throw a display message in response to a fault condition.  \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eILLYRIAN OXIMETERS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe\u003cspan class=\"apple-converted-space\"\u003e \u003c\/span\u003eTurbo Digital system includes two Illyrian II oximeters for pilot and co-pilot.  The Illyrian wearable oximeter provides continuous real-time SPO2 and heart rate information to the HealthView and to the Aithre Connect iOS app.  Advanced features include head movement and cabin altitude monitoring with haptic vibration feedback.  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAITHRE BOOM CANNULAS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhile the Turbo Digital system includes two silicone cannulas, the system additionally includes two Aithre Boom Cannulas to make oxygen delivery safer and more comfortable.  The Boom Cannula features a low profile aluminum anodized swivel adapter and an articulating boom arm, making oxygen delivery as easy and convenient as talking on the microphone.  When not in use, the Boom Arm can be pushed or swiveled up and out of the way and can be easily recharged with a new nasal arm after extended periods of use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAITHRE SHIELD CARBON MONOXIDE DETECTOR\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNo oxygen system is complete without the a carbon monoxide detector, so the Turbo Digital system includes the Shield carbon monoxide detector  The Shield CO detectors offer superior 10 year no recalibration service with sensitivity below 10 ppm and responsiveness of under 60 seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONCENTRATION MONITORING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe oxygen concentration produced by the Aithre Turbo is \u0026gt;93% for 2000 hours or 2 years, whichever comes first.  There are two primary methods to verify the concentration and ensure that the Turbo is operating correctly, using the Aithre Illyrian II wearable oximeter and using a portable oxygen concentration tester.  \u003c\/p\u003e\n\u003cp\u003eContinuously measured blood oxygen provides a direct indication of the sufficiency of breathing oxygen during flight.  The Aithre Illyrian II is the only haptic wearable that provides a continuous readout of blood oxygen to modern avionics, the Aithre HealthView, the Aithre Connect iOS app, and via the native haptic vibratory alerts.  It is the best way to monitor your blood oxygen and the verify the flow, concentration, and operation of the Turbo O2i.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eAdditionally, a portable oxygen concentration tester can be used on the ground prior to flight to test the flow and purity of oxygen generated using the Turbo. The test is simple and takes just seconds to perform using an Aithre provided oxygen concentration tester.\u003c\/p\u003e\n\u003cp\u003eThe Aithre Illyrian II and portable oxygen concentration tester are not included and must be purchased separately. \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMAINTENANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNothing is airborne for free, but operation of the Turbo is very cost-effective as compared to FBO transfilling costs.  With the Aithre Turbo, there is a sieve bed replacement that will need to occur every 2 years or 2000 hours of usage to ensure high purity oxygen generation.  There are two options for the maintenance, including either a mail-in service or a factory refurbished exchange with zero down time.  Information on the same is accessible from our website main menu or via the separate maintenance product listings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThere are a number of significant safety benefits of the Turbo.\u003c\/p\u003e\n\u003cp\u003eNotably, the Aithre Turbo does not itself store any pure oxygen so the risks associated with carrying, transporting, and filling pressurized oxygen vessels can be reduced or eliminated.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the Aithre Turbo does not include any Lithium battery.  While portable oxygen concentrators designed for medical purposes rely upon a Lithium battery, this is unacceptable for aviation environments due to the combination of pure oxygen, heat, and battery fire risk.  The Turbo relies instead on clean continuous power directly from the aircraft alternator, ship battery, and any backup ship battery available.\u003c\/p\u003e\n\u003cp\u003eOther safety features include high temperature Tefzel internal wiring, three high speed cooling fans, over temperature monitoring with over temperature shutdown, and capacitive electrical noise reduction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBACKUP CARBON FIBER COMPOSITE OXYGEN BOTTLE\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eFor casual use of the Aithre Turbo Oxygen Maker up to and around 12.5k MSL, the serious risks of hypoxia and oxygen deprivation are relatively low and failure of any part of the Turbo or electrical system can be dealt with by descending.  However, if you plan on using the Turbo for oxygen above 12.5k MSL, a simple Aithre fixed flow 47L oxygen bottle is provided with the kit for emergency backup. This lightweight carbon fiber composite bottle provides for 2 hours of continuous flow at approximately 0.5 LPM for an added layer of safety. \u003c\/p\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 18k MSL for one person and up to 15k MSL for two people (Illyrian II SPO2% determine personal altitude limits)\u003c\/li\u003e\n\u003cli\u003e\u0026gt;93% O2 purity for 2000 hours or 2 years at 1.1-1.4 LPM\u003c\/li\u003e\n\u003cli\u003e12-14V or 24-28V, 80 Watts (6 Amps at 14V)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e6.8 lbs.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e22.5 cm x 14.5 cm x 15 cm housing dimensions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003e47L bottle dimensions: 6.5 cm x 33 cm and 3 lbs. filled\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003ePush button activation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated flow, pressure altitude, humidity, and temperature monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTriple dual ball bearing cooling fans\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOver-temperature protection and fault outputs\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eAithre Connect iOS compatible\u003c\/li\u003e\n\u003cli\u003e2 year consumable lifetime with mail-in service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eINCLUDED\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAithre Turbo oxygen maker\u003c\/li\u003e\n\u003cli\u003e47L carbon fiber composite oxygen bottle fixed flow backup\u003c\/li\u003e\n\u003cli\u003eAithre silicone cannulas (2)\u003c\/li\u003e\n\u003cli\u003eIllyrian II Wearable Haptic Oximeter (2)\u003c\/li\u003e\n\u003cli\u003eAithre Boom Cannula (2)\u003c\/li\u003e\n\u003cli\u003eAithre Shield EX 3.0 (for Experimental) or Aithre Shield eDot 5.0 (for Certified)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePlumbing kit, fittings, cannula ports, placards, including backup kit\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRECOMMENDED COMPANION SAFETY PRODUCTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAithre Turbo Oxygen Concentration Tester \u003c\/li\u003e\n\u003cli\u003eHealthView Biometric Avionics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eBOTTLE SHIPPED EMPTY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eNo oxygen is contained in the bottle when shipped\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eBOTTLE SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eCarbon fiber \u0026amp; aluminum construction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003e2.5 inches x 12.5 inches overall\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003e3 lbs. (filled) \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003e47 L oxygen volume @ 2000 PSI (0.36 L liquid volume)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003e2000 PSI working pressure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003e3000 PSI maximum rating\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003e15 year bottle service life (retesting every 5 years)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eFixed flow regulator preset to 0.5LPM\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eBOTTLE REGULATION NOTICES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eCE Certificate: Bottle certified CE 1282 and inspected\/tested to ISO11119-3 international standards\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eNOT DOT approved: Carrier shipment in the U.S. requires the bottle to be empty with no pressure and no compressed oxygen\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003ePersonal portable use only - not approved for commercial use\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eNot approved for commercial flight: No gas cylinder of any type can be carried or checked on commercial flights with very limited exceptions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eNot FDA approved for medical: Do not use to treat or prevent a disease or for any medical purpose.  \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Aithre Inc","offers":[{"title":"Default Title","offer_id":50260004110556,"sku":"ATO2G02","price":4995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/8661\/5516\/files\/TurboFrontwApp.webp?v=1778612125","url":"https:\/\/shop.midwestpanels.com\/products\/aithre-turbo-oxygen-maker-digital-installed","provider":"Midwest Panel Builders","version":"1.0","type":"link"}